Improving plant efficiency does
not always save energy.

By Blaine Hanson

Editor's Note: The following story is courtesy of California Agriculture, Volume 56 Number 4, ©Regents, University of California.

California's energy crisis in 2001 resulted in a state-funded program for testing irrigation pumps and improving plant efficiency, with the goal of reducing energy use in California agriculture. Yet in reality, improving pumping plant efficiency may not actually translate into savings. To reduce electrical energy use, the kilowatt-hours must decrease because of fewer kilowatts or less operating time, or both.

In order to evaluate the efficiency of various energy-improving adjustments, we studied several operations at pumping plants in the San Joaquin Valley. These included adjusting impellers, repairing worn pumps, replacing mismatched pumps and using more energy-efficient motors. We found that adjusting or repairing worn pumps may actually increase energy use, unless the operating time of the pumping plant is reduced. Multiple pump tests of a pumping plant are recommended, to help evaluate possible reasons for low efficiency. Pumping plant operators should also obtain the manufacturer's performance curves to use in the evaluation process.

A QUESTION POSED

In the late 1980s, the question "Does improving pumping plant efficiency save energy?" was posed to a group of growers and utility company representatives in Salinas, Calif. Most of the growers said no, while most of the utility employees said yes. Before this meeting, the utility company had spent a great deal of money to improve the efficiency of irrigation pumping plants in the Salinas area. The goal was to improve the ratio of pump output horsepower to input horsepower; in other words, to make the plants more efficient by pumping a greater volume or pressure of water while using the same or less energy.

Pump efficiency is a measure of the amount of power produced by the pump per unit of input power. The power (rate of energy use) produced by a pump, called the water horsepower, depends on the pump capacity or flow rate, pressure developed by the pump, and the amount of pumping lift in the well (pumping lift is the elevation difference between the discharge of the pump and the pumping water level in the well). The higher the efficiency, the more power that is produced per unit of input power.

Electricity users pay for energy based on the number of kilowatt-hours (kwh) consumed (plus fixed charges). The kilowatt is the power demand of the electric motor; 1 kilowatt equals 1.34 horsepower. The hours are the operating time of the motor. To reduce electrical energy use, the kilowatt hours must decrease because of fewer kilowatts or less operating time, or both. Regardless of the claims about a proposed energysaving measure, if the number of kilowatts or the operating time is not reduced, no energy savings will occur.

IMPROVING EFFICIENCY

Options for improving pumping plant efficiency include adjusting impellers, repairing or replacing worn pumps, replacing mismatched pumps, and converting to energy-efficient electric motors. The effect of these options on energy use was evaluated using data collected over the past 20 years from numerous pumping plant tests conducted by the author, utility companies and companies that install and maintain pumps.

Adjusting lmpellers. Maintaining the appropriate clearance between the bottom of the vanes of a semi-open impeller and the bowl housing is critical for efficient pump performance. Wear caused by sand in the well water can increase the clearance between the impellers and housing, and reduce pumping plant efficiency. Efficiency can be partially restored by adjusting the impellers. This involves slightly lowering the pump shaf and, in turn, the impellers, by rotating the nut at the top of the shaft. This adjustment will not work for enclosed impellers.

When we adjusted the impellers of four pumps, both pump capacity and overall efficiency increased considerably. Total head increased slightly, because pumping lift only contributed to total head. However, for all four pumps, impeller adjustments increased input horsepower. Therefore, if the pumps are operated for the same amount of time after the adjustment (a common practice), energy use will increase.

Energy use will decrease only if the operating time is decreased by pumping the same volume of water after the adjustment as before. For these data, the increase in energy costs ranged from 8.3 to 18.2 percent for the same operating time before and after the adjustment. For tests 1, 3 and 4, the decrease in energy costs ranged from 12 to 22.4 percent to pump the same volume of water. For test 2, energy costs increased by 6 percent. In this case, the increase in pump capacity was insufficient to offset the increase in input horsepower because part of the increased pump output also contributed to increased total head.

Repairing Worn Pumps. Repairing a worn pump can increase capacity, total head and overall efficiency. However, for this data the input horsepower increased from 83 to 89. This behavior may be typical of many repaired pumps. A summary of 63 data sets of pump performance before and after repair shows increases of 39 percent, 0.5 percent and 33 percent in pump capacity, total head and overall efficiency, respectively. The small increase in total head occurred because pumping lift was the main contributor. However, the repair increased the input horsepower for 58 percent of the pumping plants, with an average increase of 17 percent. For these pumping plants, using the same operating time before and after the pump repair will increase energy use by 17 percent. However, pumping the same volume decreases the average energy use by 22 percent. For many pumping plants, reducing the operating time may be necessary to realize any energy savings from pump repairs.

Operators of irrigation pumping plants commonly run repaired or adjusted pumps for the same amount of time after repairs or adjustments as they did before. Operating times are often based on the management and operating requirements of the particular irrigation system; as a result, it may not be possible to reduce operating time in many cases. The practice of not reducing operating times is what led to the growers'response in Salinas; it is possible that most irrigators were unaware of the need to reduce operating times and, as a result, were using more energy after their pumps were repaired.

Replacing Mismatched Pumps. A performance characteristic of deep-well turbine and centrifugal (booster) pumps is that as pump capacity increases, pump efficiency increases to a maximum and then decreases. New pumps should be selected to provide the desired flow rate and total head near the point of maximum efficiency, which minimizes the horsepower demand of the pump. Initially efficient pumps can become inefficient because of changes in operating conditions, such as different groundwater levels or alterations in discharge to pressurized irrigation systems, even though the pump is operating properly (no wear).

A pump operating properly, but not near the point of maximum efficiency is said to be mismatched to the operating conditions. Used pumps are also candidates for being mismatched. To restore the pumping plant's efficiency, the mismatched pump must be replaced with one providing the desired total head and capacity near maximum efficiency. This change reduces the kilowatt demand of the pump and results in energy savings even if the operating time is unchanged.

A review of pump test data from a pump revealed overall efficiency of 48 percent. However, an efficiency of 57 percent was found by testing the pump under several different conditions. This relatively high efficiency suggested a mismatched pump. An analysis showed that replacing the inefficient pump with one producing the same output at an efficiency of 60 percent would reduce the input horsepower from 112 to 90, for a 19.6 percent reduction in energy use.

Using Energy-Efficient Electric Motors. Energy-efficient electric motors need less input horsepower than standard motors. Buying an energ-yefficient motor for a new irrigation pumping plant is more economical than retrofitting an existing pumping plant. For example, an energy-efficient, 100-horsepower motor can cost $6,000, compared with $5,000 for a standard motor. The input horsepower of the energy-efficient moto rwill be compared with 109 for the standard motor. At a typical cost of $0.1 per kilowatt-hour operating the pump for 2,000 hours per year will save $746, with a simple payback period of 1.3 years. The payback period for retrofitting, on the other hand, is eight years.

EVALUATING PLANT PERFORMANCE

Pumping plants should be evaluated every several years to determine the status of the pump and possible reasons for poor efficiency. Evaluating a pumping plant requires a pump test, during which capacity (flow rate), lift, discharge pressure and input horsepower are measured. The overall pumping plant efficiency is calculated from these data, and can then be compared with the standards for correcting electric pumping plants.

Pump wear or a mismatched pump can cause poor efficiency. Likewise, repairing a mismatched pump may not improve efficiency. So how can one determine if a pump is mismatched or worn?

One approach is to conduct multiple pump tests, each under different operating conditions. These conditions can be imposed on a pump simply by partially closing a valve in the discharge pipe or changing the number of sprinkler pipelines or drip lines that are irrigated. An efficiency of about 60 percent or more for one of the tests indicates a mismatched pump under the normal operating conditions.

A second approach is to compare pump test data under normal operating conditions with the manufacturer's performance data. Manufacturers provide information for each pump on the relationships between capacity and total head, efficiency and brake horsepower. By comparing the total head of the pump test with the manufacturer's total head at the measured capacity, one can evaluate if a low efficiency is due to wear or mismatched operating conditions.

For example, a pump test conducted in 1984 showed an efficiency of 54 percent. However, the deviation of the test point from the manufacturer's curve was about the same as that of the 1983 test point. The following year (1985), pump efficiency rebounded. This behavior suggests that the 1984 efficiency was due to a mismatched condition. The 1985 point, which shows efficiency similar to the 1983 test, verifies this. However, a second data set showed that the deviation between pump test data and the manufacturer's performance curve increased with time, indicating possible increasing wear.

Some caution is necessary in taking this approach. Poor-quality pump test data may prevent an accurate evaluation of the pumping plant. Cascading water in a well may prevent good measurements of pumping lift. Poor test conditions may also prevent good flowrate measurements. The test section should have eight to 10 pipe diameters of straight pipe immediately upstream of a flow meter and two pipe diameters downstream to prevent errors due to excessive turbulence in the water. For a 10-inch pipe, a straight section 80 to 100 inches long is recommended. However, research has shown that propeller flow meters are less susceptible to large errors from turbulence caused by bends or elbows and checks valves upstream from the meter.

Impeller adjustments, made by turning the nut at the top of the pump shaft, can improve pump efficiency, but that may not translate into energy savings unless operating time is reduced.

ENERGY SAVINGS

This series of studies shows that simply improving pumping plant efficiency does not guarantee energy savings. In fact, adjusting or repairing worn pumps may increase energy use unless the operating time of the pumping plant is reduced.

Sometimes, adjusting the operating time still will not save energy if part of the increase in pump output contributes to a significant total head increase in addition to a capacity increase. With a higher flow rate, pumping plant operators can reduce operating time, with either less irrigation time per set or greater acreage irrigated per set. Opportunities for reducing the operating time will depend on site-specific conditions, such as the irrigation method and its design and management characteristics. If reducing the operating time is not possible, the improved efficiency may result in more crop yield and revenue due to more water applied to a field.

Multiple pump tests (at least three) of a pumping plant are recommended, to help evaluate possible reasons for low efficiency. Pumping plant operators should also obtain the manufacturer's performance curves to use in the evaluation process.

The author is extension irrigation and drainage specialist, Department of Land, Air and Water Resources, UC Davis.

For references, data tables and efficiency formulas, visit the IBT section on this Web site.